<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-02 15-49-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 57 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.6 kHz -85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 18980 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,5 dBr 5,69 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/07/02 15.48.13 Total samples: 18980 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 6,4 dBr MIN: 4,5 dBr AVE: 5,69 dBr % above 12,2 dBr: 0,0 Last value: 6,4 dBr (2025/07/02 15.48.12) 15.34 15.36 15.38 15.40 15.42 15.44 15.46 15.48 0 2 4 6 Pm [dBr]